Previous Article | Next Article ![]()
Clinical and Diagnostic Laboratory Immunology, January 2002, p. 138-143, Vol. 9, No. 1
1071-412X/01/$04.00+0 DOI: 10.1128/CDLI.9.1.138-143.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.
Division of Immunologic and Infectious Diseases,1 Center for AIDS Research, University of Pennsylvania Medical School, Philadelphia, Pennsylvania 19104,2 Division of Neurology and Neurology Research, Department of Pediatrics, Joseph Stokes, Jr., Research Institute at the Childrens Hospital of Philadelphia3
Received 30 July 2001/ Returned for modification 24 September 2001/ Accepted 15 October 2001
|
|
|---|
|
|
|---|
SP is synthesized from four preprotachykinin A (PPT-A) mRNAs (
, ß,
, and
) (21). These isoforms of mRNA are the result of alternative mRNA splicing of the primary transcript of the PPT-A gene (6). The sequence in exon 3 encodes SP, while the sequence in exon 6 encodes neurokinin A (NKA). The SP sequence is encoded by all four isoforms (
, ß,
, and
) of PPT-A mRNA, whereas the NKA precursor sequence is present only in ß and
PPT-A mRNAs. These four isoforms of PPT-A mRNA differ in their exon combinations (Fig. 1). ß PPT-A mRNA contains all seven exons of the corresponding gene, while
PPT-A mRNA lacks exon 6,
PPT-A mRNA lacks exon 4 (14, 25), and
PPT-A mRNA lacks both exon 4 and exon 6 (6, 13).
![]() View larger version (16K): [in a new window] |
FIG. 1. Alternative splicing products of PPT-A mRNA transcripts. Exons 2, 3, 4, 5, 6, and 7 are indicated. Exon 3 encodes SP, and exon 6 encodes NKA. The locations and orientations (arrows) of primers HSP3', HSP4, HSP5, and the SP MB probe are indicated.
|
, ß,
, and
) of PPT-A mRNA transcripts, resulting in a single 121-bp fragment that can be measured quantitatively by the SP mimic-based PCR assay (17). Establishment of the SP mimic-based PCR assay, however, is laborious and needs several dilutions from 1:10 to 10:1 (its dynamic range) for each unknown sample in order to determine a target-to-mimic ratio. Although this assay can determine the number of SP mRNA transcripts in a sample, the differences in SP mRNA copy numbers between samples must be twofold or higher. In addition, the mimic-based PCR quantification involves post-PCR manipulations which are laborious and time-consuming. Recently, a real-time PCR analysis has been developed (10, 31). The real-time PCR method solved these problems with real-time monitoring of the PCR amplification process. The monitoring of the entire reaction rather than just the end product permits the quantification to be based on the early, exponential phase of the reaction. Most importantly, the real-time system for PCR quantification is a probe-based analysis. The molecular beacon [MB] probe has been reported to be used for the construction of probes that are critical for real-time detection of nucleic acid hybridization events (31). Recent studies have successfully used the MB probe for a variety of real-time PCR applications (5, 28, 3032). The MB probe is a single-stranded nucleic acid molecule that possesses a stem-and-loop structure. In real-time PCR, the MB probe as well as the primers hybridize to the templates during the annealing stage. As the target strands synthesized in a reaction accumulate, the fraction of the MB probe that binds to the targets increases, resulting in a brighter fluorescent signal. Here, we describe a rapid and reproducible RT-PCR method with specific SP primers and a probe that allows the quantification of SP mRNA copies in human immune cells with the ABI Prism 7700 real-time sequence detection system (the SP real-time RT-PCR assay). |
|
|---|
RNA extraction. Total RNA was extracted from MDMs, PBLs (stimulated with phytohemagglutinin P for 72 h), fetal brain microglia, and NT-2N cells (106 cells) with Tri-Reagent (Molecular Research Center, Cincinnati, Ohio), as instructed by the manufacturer. In brief, the total RNA was extracted in a single step by guanidinium thiocyanate-phenol-chloroform extraction. After centrifugation at 13,000 x g for 15 min, the RNA-containing aqueous phase was precipitated in isopropanol. The RNA precipitates were then washed once in 75% ethanol and resuspended in 50 µl of RNase-free water.
Cloning of PPT-A cDNA.
The four isoforms of PPT-A mRNA were cloned and identified with primer pairs HSP4-HSP5 and HSP4-HSP7, as reported earlier (16, 17) (Fig. 1). Briefly, the PCR products amplified with these primers were separated on a 4% agarose gel and then purified with a Wizard PCR Preps DNA purification system (Promega, Madison, Wis.). The purified cDNAs of the PPT-A isoforms (
, ß,
,
) were then cloned into a plasmid with a Eukaryotic TA cloning kit (Invitrogen Corporation, San Diego, Calif.). The cloned plasmids containing the cDNAs of the PPT-A isoforms were then purified with a Wizard Plus Minipreps DNA purification system (Promega). The presence and orientation of the PPT-A isoform inserts were determined by restriction analysis by using EcoRV digestion and DNA sequencing. The purified plasmids were linearized by EcoRI restriction enzyme digestion and were purified by phenol-chloroform extraction and alcohol precipitation. These cloned PPT-A isoform-containing plasmids were used as a standard control for determination of the accuracy of the quantitative real-time PCR and as a template for the synthesis of mRNA in vitro to evaluate the sensitivity of the real-time RT-PCR and to make a standard curve for the real-time RT-PCR.
In vitro mRNA synthesis. PPT-A mRNA transcripts were obtained by transcription from the plasmid containing the ß-isoform cDNA insert with a MEGAshortscript kit (Ambion, Austin, Tex.). After digestion with RNase-free DNase (Promega), the resulting RNA transcripts were purified by phenol-chloroform extraction and alcohol precipitation as reported previously (16, 17). The purified mRNA was used as a standard to quantitatively measure the SP mRNA transcripts in MDMs, PBLs, and the microglia by the real-time RT-PCR with primer pair HSP4-HSP3'.
Design of molecular beacons and primers. The PCR primers and the MB probes used were designed with Primer Express software (PE Applied Biosystems) and were synthesized by Integrated DNA Technologies, Inc. (Coralville, Iowa). The HSP4-HSP3' primer pair (HSP4, 5'-CGACCAGATCAAGGAGGAACTG-3'; HSP3', 5'-CAGCATCCCGTTTGCCCATT-3'), which is specific for a 121-bp fragment of the SP transcript, was described previously (17), but with modification by the addition of 4 additional nucleotides at the 3' end of primer HSP3 (underlined) because of the design obtained with the Primer Express software. The sequences of the primers and the MB probe were selected from the sequences of exons 2 and 3 of the PPT-A gene (16) (Fig. 1) so that they amplify a single cDNA fragment that represents the total SP from transcripts of all four isoforms of PPT-A mRNA (17). The primer pair specific for glyceraldehyde-3-phosphate dehydrogenase (GAPDH) is 5'-GGTGGTCTCCTCTGACTTCAACA-3' (sense) and 5'-GTTGCTGTAGCCAAATTCGTTGT-3' (antisense). The sequences of the MB probes specific for SP and GAPDH were designed to be perfectly complementary to the target sequence in exon 3 of the SP gene and to be complementary to the sequence between the sequence of each primer in the primer pair for GAPDH, respectively. The following are the sequences of the two MB probes: SP, 5'-FAM-GCGAGCAGA-ATCGCCCGGAGACCCAAGCGCTCGC-DABCYL-3'; GAPDH, 5'-FAM-GCGAGCC-TGGCATTGCCCTCAACGACCACGCTCGC-DABCYL-3'. The underlined sequences are the stem sequences, FAM is 6-carboxyfluorescein, and DABCYL is 4-(4'-dimethylaminophenylaso) benzoic acid. The stem sequences were selected such that they would not complement the sequences within the loop region. The lengths of the MB probes were designed such that the annealing temperature is slightly higher than those for the PCR primers. The MB probes were labeled at the 5' end with FAM and the quencher DABCYL at the 3' end. The primers and MB probes were resuspended in TE (Tris-EDTA) buffer and stored at -30°C.
Reverse transcription. Total RNA (1 µg) was subjected to reverse transcription with a reverse transcription system (Promega) with random primer p(dN)6 (Roche Molecular Biochemicals, Indianapolis, Ind.) and specific primer (antisense) HSP5 (5'-GCATTGCACTCCTTTCATAAGCCA-3') for 1 h at 42°C. The reaction was terminated by incubation of the reaction mixture at 99°C for 5 min. One-tenth (100 ng) of the resulting cDNA was used as a template for PCR amplification.
Real-time PCR assay. The Perkin-Elmer ABI Prism 7700 sequence detection system was used for real-time analysis. Thermal cycling conditions were designed as follows: initial denaturation at 95°C for 10 min, followed by 45 cycles of 95°C for 15 s and 60°C for 1 min. Fluorescence measurements were recorded during each annealing step. At the end of each PCR run, the data were automatically analyzed by the system and amplification plots were obtained. For each PCR, 2 µl of cDNA template was added to 48 µl of the PCR master mixture (5 µl of 1x PCR buffer II, 5 mM MgCl2, 300 nM deoxynucleoside triphosphates, 400 nM each primer, 1.5 U of AmpliTaq Gold DNA polymerase, 400 nM MB probes, 24.7 µl of water). The PCR buffer contained 5-carboxy-X-rhodamine (ROX) (500 nM) as the reference dye for normalization of the reactions. Any possible fluctuations in the ROX signal are used to correct the sample signal. All amplification reactions were performed in duplicate. To control for the recovery of intact cellular RNA and for the uniform efficiency of each reverse transcription reaction, a GAPDH fragment was amplified by real-time RT-PCR on the same plate as that with SP cDNA. A standard curve was generated with 10-fold dilutions of total RNA quantified with a spectrophotometer. The final results were expressed as the mean number of copies of SP mRNA per microgram of total RNA. In order to prepare a standard curve for SP mRNA, 10-fold serial dilutions of ß-isoform PPT-A RNA transcripts ranging from 6 x 101 to 6 x 106 copies/2 µl were amplified.
Amplification efficiency. The efficiency of real-time amplification was determined by running a standard curve with serial dilutions of a known amount of cloned SP plasmid cDNA. A PCR that amplifies the target sequence with 100% efficiency (E) can double the amount of PCR products in each cycle. The amount of PCR products (Y) from input target molecules (Z) after n cycles can be calculated by the formula s = -1/log(1 + E) (where s is the slope), and after transformation, E is equal to 101/-s - 1 (19).
|
|
|---|
![]() View larger version (22K): [in a new window] |
FIG. 2. Sensitivity and linearity of real-time RT-PCR with RNA transcripts derived from plasmid with ß-isoform mRNA. A reading of the change in fluorescence (Rn) as a function of the cycle number is demonstrated for a range of known input numbers of copies of the SP RNA transcript. Tenfold serial dilutions of the RNA starting from 60 to 6 x 106 molecules per reaction mixture were amplified by the real-time RT-PCR. (A) Standard curve of serial dilutions of SP RNA (R2 = 0.98). (B) Amplification plot of serial dilutions of SP RNA showing the dynamic detection range of 6 orders of magnitude from 60 to 6 x 106 molecules and the sensitivity of detection of 60 SP mRNA copies per reaction mixture. NC, negative control which lacked PCR-amplified product when RT was omitted from the reverse transcription reaction with 6 x 106 molecules of SP mRNA transcripts.
|
|
View this table: [in a new window] |
TABLE 1. Reproducibility of SP real-time PCR assaya
|
![]() View larger version (13K): [in a new window] |
FIG. 3. Standard curves of PPT-A ß-isoform plasmid cDNA. The curve was made on the basis of the data from Table 1, and the CT values are the means for five runs. Tenfold serial dilutions of the cDNA ranging from 60 to 6 x 104 copies per reaction mixture were amplified by the real-time PCR. The correlation coefficient was 0.9973.
|
, ß,
, and
isoform sequences, respectively, was used as a template for the real-time PCR. As shown in Fig. 4 and Table 2, the SP sequence was efficiently amplified by the real-time PCR from plasmids containing all four isoforms of PPT-A. The slopes of the four curves were generated to compare the efficiencies of amplification among the four isoforms of PPT-A cDNA. The efficiencies of the PCR amplifications for these isoforms were between 98 and 110% (Table 2).
![]() View larger version (37K): [in a new window] |
FIG. 4. Real-time PCR amplification plot of the four isoforms of PPT-A cDNA. A reading of a change in fluorescence (Rn) as a function of the cycle numbers is demonstrated for a range of known input copy numbers of plasmids containing the four isoforms of PPT-A. Tenfold serial dilutions of the four plasmids were amplified. The input amounts of targets were 30 to 3 x 106 copies per reaction mixture for plasmids containing the , ß, , and isoforms of PPT-A, as indicated. NC, negative control, which lacked PCR-amplified product when the template was omitted.
|
|
View this table: [in a new window] |
TABLE 2. Amplification efficiencies and slopes for four isoforms of PPT-A
|
|
View this table: [in a new window] |
TABLE 3. Quantification of SP mRNA in human immune cells
|
|
View this table: [in a new window] |
TABLE 4. Intra-assay reproducibility of SP real-time PCR assaya
|
|
|
|---|
, ß,
, and
) of PPT-A mRNA in human immune cells (12, 15, 16, 18). In order to determine the total SP mRNA transcript levels, we developed a mimic-based PCR to amplify SP mRNA from all four isoforms of PPT-A mRNA transcripts in a single cDNA product with the HSP4-HSP3 primer pair (17). The HSP3 primer sequence is from within the exon 3 sequence of the SP gene (16) (Fig. 1). However, quantification of SP mRNA levels by the mimic-based PCR can be problematic due to the exponential nature of PCR analyses, since small variations in amplification efficiency can lead to dramatic changes in product yields, which obscures differences in the levels of SP mRNA during amplification. This is particularly true for the quantification of low levels of SP mRNA in human immune cells. In the present study, we have successfully used the real-time PCR for the quantification of SP mRNA in human MDMs, PBLs, and microglia (Table 3). The microglia had the highest levels of SP mRNA transcripts among the three types of cells tested, which is in agreement with our previous comparisons with these cell types by mimic-based PCR (18). The ability to monitor the real-time progress of the amplification completely revolutionizes the PCR-based quantification of DNA and RNA. In real-time PCR, reactions are characterized by the point in time during cycling when the amplification of a PCR product is first detected rather than the amount of PCR product accumulated at the end of the entire PCR process. The higher the numbers of copies of the nucleic acid target at the start of the reaction, the sooner a significant increase in fluorescence is observed (11) and the lower the CT value is. Real-time PCR allows the CT value to be observed when the PCR amplification is still in the exponential phase. Therefore, the CT value is a more reliable measurement of the number of copies of mRNA or DNA at the start of the reaction.
Thus, we have developed an MB probe-based real-time RT-PCR assay for the quantification of SP mRNA copy numbers in human immune cells. We designed an SP-specific MB probe and a pair of SP-specific primers to target the sequence of a single cDNA fragment that reflects total SP mRNA from all four isoforms of PPT-A mRNA. Since it has a wide dynamic detection range (6 x 101 to 6 x 105 copies per reaction), there is no need to dilute or concentrate the samples, which was one of the problems encountered with the mimic-based SP PCR (17). This SP MB-based RT-PCR is much less cumbersome, and the costs associated with the use of this system are the same as those associated with the use of the regular RT-PCR. Because this system allows processing of multiple samples with minimal labor time, the risk of carryover contamination due to post-PCR sample manipulation is minimal. In addition, this assay is highly specific, since the assay uses both specific primers and a probe (the MB probe) to identify SP mRNA transcripts in human immune cells. The SP MB probe-based real-time PCR has an excellent reproducibility (Tables 1 and 4). Furthermore, all four isoforms of PPT-A cDNA in cloned plasmids were efficiently amplified by the SP real-time PCR assay (Fig. 4; Table 2). Although the SP real-time PCR assay that we have developed can amplify cDNA that reflects transcripts of all four isoforms of SP mRNA, it is not feasible to amplify a transcript of a particular SP mRNA isoform. This limitation is due to the PPT-A genome structure and the combination of the seven exons for each isoform of PPT-A mRNA (Fig. 1) (17). However, the assay with different primer pairs has the ability to amplify mRNA of the PPT-A
and
isoforms or mRNA of the ß and
isoforms (17).
In summary, we have successfully used a newly developed MB probe-based RT-PCR assay to quantitatively measure the total levels of SP mRNA transcripts in both human neural cells and immune cells. Our data demonstrate that this method is precise, sensitive, highly reproducible, and particularly useful for the quantification of SP mRNA levels in nonneuronal cells that have very low levels of expression of the SP gene. This method has the potential for widespread application in basic and clinical studies in neuroimmunology.
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2010 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»