This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sang, C. T.
Right arrow Articles by Devine, P. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sang, C. T.
Right arrow Articles by Devine, P. L.

 Previous Article  |  Next Article 

Clinical and Diagnostic Laboratory Immunology, January 1998, p. 7-10, Vol. 5, No. 1
1071-412X/98/$04.00+0
Copyright © 1998, American Society for Microbiology. All rights reserved.

Evaluation of a Commercial Capture Enzyme-Linked Immunosorbent Assay for Detection of Immunoglobulin M and G Antibodies Produced during Dengue Infection

Chew Theng Sang,1 Andrea J. Cuzzubbo,2 and Peter L. Devine3,*

Department of Pathology, Singapore General Hospital, Singapore, Singapore,1 and PanBio Pty Ltd., East Brisbane,2 and Clinical Sciences, Royal Brisbane Hospital, Brisbane,3 Australia

Received 23 June 1997/Returned for modification 25 July 1997/Accepted 16 September 1997

A commercially available capture enzyme-linked immunosorbent assay (ELISA) for the detection of specific immunoglobulin M (IgM) and IgG antibodies produced during dengue infection (PanBio Dengue Duo) was evaluated with paired serum specimens from 176 patients. Diagnosis was based on a hemagglutination inhibition (HAI) assay, with patients having either primary dengue (n = 90), secondary dengue (n = 58), or no dengue (n = 28) infection. The combined use of IgM and IgG (sensitivity, 99%; specificity, 96%) was superior to the use of IgM alone (sensitivity, 88%; specificity, 96%) or IgG alone (sensitivity, 85%; specificity, 96%). Furthermore, with the first serum sample of the pair of serum samples, the ELISA was able to diagnose significantly more cases of dengue than the HAI assay (55% versus 14%). The results of the IgG capture ELISA gave a significant correlation with those of the HAI assay (r = 0.91; P < 0.0001), and the IgG capture ELISA could be used to distinguish between primary and secondary infection. The best distinction was observed when an IgG cutoff ratio of 3.0 was used, with 88% of primary infections and 98% of secondary infections being correctly classified. This ELISA should prove to be useful in the clinical diagnosis of dengue infection.


* Corresponding author. Mailing address: B Floor, Clinical Sciences, Royal Brisbane Hospital, Herston 4129, Queensland, Australia. Phone: 61-7-33655202. Fax: 61-7-33655203.


Clinical and Diagnostic Laboratory Immunology, January 1998, p. 7-10, Vol. 5, No. 1
1071-412X/98/$04.00+0
Copyright © 1998, American Society for Microbiology. All rights reserved.



This article has been cited by other articles:

  • Charrel, R. N., de Lamballerie, X. (2002). Low Specificity of an Immunochromatographic Serological Assay for Diagnosis of Dengue Fever in Travelers Returning with Malaria. CVI 9: 1400-1400 [Full Text]  
  • Cuzzubbo, A. J., Endy, T. P., Nisalak, A., Kalayanarooj, S., Vaughn, D. W., Ogata, S. A., Clements, D. E., Devine, P. L. (2001). Use of Recombinant Envelope Proteins for Serological Diagnosis of Dengue Virus Infection in an Immunochromatographic Assay. CVI 8: 1150-1155 [Abstract] [Full Text]  
  • Kit Lam, S., Lan Ew, C., Mitchell, J. L., Cuzzubbo, A. J., Devine, P. L. (2000). Evaluation of a Capture Screening Enzyme-Linked Immunosorbent Assay for Combined Determination of Immunoglobulin M and G Antibodies Produced during Dengue Infection. CVI 7: 850-852 [Abstract] [Full Text]  
  • Cuzzubbo, A. J., Vaughn, D. W., Nisalak, A., Solomon, T., Kalayanarooj, S., Aaskov, J., Dung, N. M., Devine, P. L. (1999). Comparison of PanBio Dengue Duo Enzyme-Linked Immunosorbent Assay (ELISA) and MRL Dengue Fever Virus Immunoglobulin M Capture ELISA for Diagnosis of Dengue Virus Infections in Southeast Asia. CVI 6: 705-712 [Abstract] [Full Text]  
  • Porter, K. R., Widjaja, S., Darmawan, H., Lohita, , Hadiwijaya, S. H., Maroef, C. N., Suharyono, W., Tan, R. (1999). Evaluation of a Commercially Available Immunoglobulin M Capture Enzyme-Linked Immunosorbent Assay Kit for Diagnosing Acute Dengue Infections. CVI 6: 741-744 [Abstract] [Full Text]  
  • Branch, S. L., Levett, P. N. (1999). Evaluation of Four Methods for Detection of Immunoglobulin M Antibodies to Dengue Virus. CVI 6: 555-557 [Abstract] [Full Text]  
  • Cuzzubbo, A. J., Vaughn, D. W., Nisalak, A., Suntayakorn, S., Aaskov, J., Devine, P. L. (1998). Detection of Specific Antibodies in Saliva during Dengue Infection. J. Clin. Microbiol. 36: 3737-3739 [Abstract] [Full Text]