Using 255 serum samples with various reactivities, we evaluated the
Syphilis Fast latex agglutination test (Syphilis Fast) against the
Treponema pallidum particle agglutination test (TP-PA) for
confirming a diagnosis of syphilis. We found 98.8% agreement between
the Syphilis Fast and the TP-PA. The Syphilis Fast, however, had a
couple of advantages over the TP-PA: the test takes only 8 min to
perform and produces results that are easy to read. It appears to be a
good confirmatory test for syphilis, especially for point-of-care
clinics such as prenatal or sexually transmitted disease clinics.